You are here: Home / COVID-19

SARS-CoV-2 Antigen Rapid Detection Kit

Latex Chromatography

SARS-CoV-2 Antigen Rapid Detection Kit
Size (CM): 13.5 * 7.8 * 2
Net weight (g): 26.03

1 Test / Kit

Kit Components:

1 Rapid SARS-CoV- 2 Antigen Test Card

(sealed foil pouch)

1 Sterilized swab

1 Sample lysis solution

1 IFU

1 Biohazard waste bag

SARS-CoV-2 Antigen Rapid Detection Kit
Size (CM): 18.5*11.2*5.2
Net weight (g): 54.8

5 Tests / Kit

Kit Components:

5 Rapid SARS-CoV-2 Antigen Test Cards (sealed foil pouch)

5 Sterilized swabs

5 Sample lysis solutions

1 IFU

5 Biohazard waste bags

SARS-CoV-2 Antigen Rapid Detection Kit
Size (CM): 22.5*18.2*9.3
Net weight (g): 274

25 Tests / Kit

Kit Components:

25 Rapid SARS CoV-2 Antigen Test Cards (sealed foil pouch)

25 Sterilized swabs

25 Sample lysis solutions

1 IFU

 25 Biohazard waste bags

Test Procedures

Step 1

The sampler holds the swab and inserts it into the nostril 2.5-3cm until there is a slight resistance. At moderate pressure, move the swab 4-6 times around the inner wall of the nose for at least 15 seconds to collect as many cells and mucus as possible. Repeat the process with the same swab on the other nostril.

Step 2

Remove an extraction tube from the kit and a test box from the film bag by tearing the notch.

Put them on the horizontal plane.

Step 3

After sampling, soak the smear below the liquid level of the sample extraction buffer,rotate and press 5 times. Immerse time of smear at least 15s.

Step 4

Remove the swab and press the edge of the tube to squeeze out the liquid in the swab. Throw the swab into the biological hazardous waste.

Step 5

Fix the pipette cover firmly on the top of the suction tube. Then gently turn the extraction tube 5 times.

Step 6

Transfer 3 drops (about 100 μL) of the sample to the sample surface of the test band and start the timer. Note: if frozen samples are used, the samples must have room temperature.

Step 7

Read the results in 15-20 mins. Do not interpret the result exceed 20 mins.

Do not eat, drink, smoke or smoke electronic cigarettes within 30mins before the test.

Interpretation of Results

Positive

Colored bands appear at both test line (T) and control line (C). It indicates a positive result for the SARS-CoV-2 antigens in the specimen.

Negative

Colored band appear at control line (C) only. It indicates that the concentration of the SARS-CoV-2 antigens does not exist or below the detection limit of the test.

Invalid

No visible colored band appears at control line after performing the test. The directions may not have been followed correctly or the test may have deteriorated. It is recommended that the specimen be re-tested.

SARS-CoV-2 Saliva Antigen Rapid Detection Kit

Latex Chromatography

 

 Sample type: Saliva  Time to result: 15-20 mins  Sensitivity : 97.83%  Specificity : 98.23% Accuracy : 98.09%

SARS-CoV-2 Saliva Antigen Rapid Detection Kit
Size (CM): 13.5*7.8*2
Net weight (g): 22.06

1 Test / Kit

Components:

 1 Test kitMouth-type

1 IFU

SARS-CoV-2 Saliva Antigen Rapid Detection Kit
Size (CM): 18.5*11.2*5.2
Net weight (g): 66.08

5 Tests / Kit

Components:

 5 Test kitsMouth type

 1 IFU

SARS-CoV-2 Saliva Antigen Rapid Detection Kit
Size (CM): 22.5*18.2*9.3
Net weight (g): 246.57

25 Tests / Kit

Kit Components:

25 Test kitsMouth type

1 IFU

Test Procedures

Step 1

Open the bag, take out the cassette from the package, and place it on a clean, level surface

Step 2

Remove the lid and put the cotton core directly under the tongue for two minutes to soak the saliva (Note: Keep your tongue pressed against the wick and don't roll it up). The wick must be immersed in the saliva for 2 mins or until the liquid appears in the viewing window of the cassette.

Step 3

After 2 mins, remove the test object from the sample or under the tongue. Close the lid, and place it on a flat surface.

Step 4

Start the timer. Read the result after 15 mins.

Interpretation of Results

Positive

Colored bands appear at both test line (T) and control line (C). It indicates a positive result for the SARS-CoV-2 antigens in the specimen.

Negative

Colored band appear at control line (C) only. It indicates that the concentration of the SARS-CoV-2 antigens does not exist or below the detection limit of the test.

Invalid

No visible colored band appears at control line after performing the test. The directions may not have been followed correctly or the test may have deteriorated. It is recommended that the specimen be re-tested.

ARS-CoV-2 Saliva Antigen Rapid Detection Kit

Latex Chromatography

 

 Sample type: Saliva  Time to result: 15-20 mins  Sensitivity : 97.83%  Specificity : 98.23% Accuracy : 98.09%

w7
Size (CM): 13.5*7.8*2
Net weight (g): 26.7

1 Test / Kit

Kit Components:

 1 Rapid SARS-CoV-2 Antigen Test Card(sealed foil pouch)

 1 Disposable paper cup

 1 Sample lysis solution

 1 Disposable dropper

 1 IFU

 1 Biohazard waste bag

w8
Size (CM): 18.5*11.2*5.2
Net weight (g): 89.03

5 Tests / Kit

Kit Components:

 5 Rapid SARS-CoV-2 Antigen Test Cards(sealed foil pouch)

 5 Disposable paper cups

 5 Sample lysis solutions

 5 Disposable droppers

 1 IFU

 5 Biohazard waste bags

w9
Size (CM): 22.5*18.2*9.3
Net weight (g): 361.32

25 Tests / Kit

Kit Components:

 25 Rapid SARS-CoV-2 Antigen Test Cards(sealed foil pouch)

 25 Disposable paper cups

 25 Sample lysis solutions

 25 Disposable droppers

 1 IFU

 25 Biohazard waste bags

Test Procedures

Step 1

The sampler holds the swab and inserts it into the nostril 2.5-3cm until there is a slight resistance. At moderate pressure, move the swab 4-6 times around the inner wall of the nose for at least 15 seconds to collect as many cells and mucus as possible. Repeat the process with the same swab on the other nostril.

Step 2

Remove an extraction tube from the kit and a test box from the film bag by tearing the notch.

Put them on the horizontal plane.

Step 3

After sampling, soak the smear below the liquid level of the sample extraction buffer,rotate and press 5 times. Immerse time of smear at least 15s.

Step 4

Remove the swab and press the edge of the tube to squeeze out the liquid in the swab. Throw the swab into the biological hazardous waste.

Step 5

Fix the pipette cover firmly on the top of the suction tube. Then gently turn the extraction tube 5 times.

Step 6

Transfer 3 drops (about 100 μL) of the sample to the sample surface of the test band and start the timer. Note: if frozen samples are used, the samples must have room temperature.

Step 7

Read the results in 15-20 mins. Do not interpret the result exceed 20 mins.

Do not eat, drink, smoke or smoke electronic cigarettes within 30mins before the test.

Interpretation of Results

Positive

Colored bands appear at both test line (T) and control line (C). It indicates a positive result for the SARS-CoV-2 antigens in the specimen.

Negative

Colored band appear at control line (C) only. It indicates that the concentration of the SARS-CoV-2 antigens does not exist or below the detection limit of the test.

Invalid

No visible colored band appears at control line after performing the test. The directions may not have been followed correctly or the test may have deteriorated. It is recommended that the specimen be re-tested.

Please Enter Your Information

QUIK LINK

PRODUCTS

QUIK LINK

CONTACT

Address: No.1203,Jianyu Mansioin, No.100 Huju Road, Nanjing, Jiangsu, China

Tell: 0086-025-85869218

Mobile: +86-18652030953

© 2022 Nanjing Mayeet Medical Import & Export Co.,Ltd.  Sitemap   |   Support by Leadong.com